Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Braz. oral res. (Online) ; 37: e053, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439751

ABSTRACT

Abstract Halitosis affects all populations worldwide. The presence of chronic halitosis may be related to a health problem. Patients with bad breath usually seek a gastroenterologist and, in some cases, invasive and expensive exams, such as digestive endoscopy, are performed to investigate the etiology of halitosis. This study aimed to investigate whether the prevalence of bad breath in patients diagnosed with dyspepsia (any pain or discomfort in the upper abdomen) is higher than or equivalent to that in non-dyspeptic patients. This is a cross-sectional study that included 312 patients from university hospitals in the city of Rio de Janeiro (141 dyspeptic patients and 171 non-dyspeptic ones). The presence of halitosis was defined based on different cutoff points. Association analyses were performed using a log-binomial model and 95% confidence intervals were calculated for the coefficients, adjusting for sex and age. The equivalence test (Westlake) was used to test the hypothesis of equivalence between the proportions of patients with bad breath in the two groups (dyspeptic vs. non-dyspeptic), considering an equivalence band of ± 15%. The prevalence of bad breath ranged from 30% to 64% according to the definition of bad breath. Dyspepsia was not associated with bad breath in any of the three definitions of bad breath (two specific ones and a sensitive one). The proportion of patients with marked bad breath was equivalent in patients with and without dyspepsia.

2.
Chinese Journal of Dermatology ; (12): 1001-1004, 2021.
Article in Chinese | WPRIM | ID: wpr-911562

ABSTRACT

Objective:To deliver understanding of the latest research progress on clinical trials and approval of dermatological drugs in China in 2020.Methods:A registration and information disclosure platform for drug clinical studies and a query system for domestic and imported drugs in the National Medical Products Administration of China were searched for registered clinical trials and approved dermatological drugs, respectively. The number and stages of clinical trials, indications and classification of involved products, and listed dermatological drugs in 2020 were summarized and depicted.Results:There were 157 dermatological drug trials registered in China in 2020, accounting for 6.16% of all the 2 548 clinical drug trials, including 127 (80.9%) initiated by Chinese pharmaceutical enterprises and 25 (15.9%) international multicenter trials. Among the 127 drug trials initiated by Chinese pharmaceutical enterprises, bioequivalence trials were mostly common, accounting for 55.9% (71/127) . Compared with global pharmaceutical enterprises, domestic pharmaceutical companies initiated significantly decreased proportions of international multicenter trials (1.9% [3/157] vs. 14.0% [22/157], P < 0.001) , but significantly increased proportions of phaseⅠclinical trials and bioequivalence trials (24.4% [31/127] vs. 10.0% [3/30], 55.9% [71/127] vs. 0, respectively, both P < 0.001) . Totally, 90 kinds of dermatological drug were involved in all the trials, psoriasis, atopic dermatitis and melanoma were the most common indications, and innovative drugs accounted for 53.3% (48/90) ; the proportion of innovative drugs was significantly lower in domestic pharmaceutical companies than in global pharmaceutical companies (43.2% [32/74] vs. 16/16, P < 0.001) . In addition, 28 dermatological drugs developed by 22 pharmaceutical companies were approved in China in 2020, of which 21 drugs were developed by domestic pharmaceutical companies. Conclusion:Clinical drug trials carried out by domestic pharmaceutical companies mostly focus on generic drugs, and it is still necessary for domestic pharmaceutical companies to further improve the innovation ability.

3.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1509004

ABSTRACT

Los medicamentos genéricos desempeñan un papel importante en los sistemas de atención de salud, ya que representan una alternativa eficaz más asequible para la población. En el Perú, se estableció un reglamento que regula la intercambiabilidad de medicamentos genéricos (también llamados multifuentes), que define los procedimientos y requisitos a seguir para desarrollar estudios de equivalencia terapéutica in vivo e in vitro, siguiendo el enfoque de aplicación gradual y el criterio de riesgo sanitario. El cumplimiento de este reglamento permitirá un mayor acceso a medicamentos genéricos eficaces, seguros y de calidad. Mientras tanto, se siguen comercializando genéricos en ausencia de estudios de equivalencia terapéutica. Los estudios demuestran que algunos medicamentos fallaron en las comparaciones in vivo e in vitro con el medicamento de referencia. Esta implementación representa un gran desafío para los laboratorios fabricantes y los titulares de registros sanitarios a fin de demostrar la intercambiabilidad de sus productos farmacéuticos con el medicamento de referencia.


Generic drugs play an important role in healthcare systems as they represent an effective and more affordable alternative for the population. In Peru, a regulation of interchangeability of generic drugs (also called multisource drugs) was stablished to define the procedures and requirements for developing in vivo and in vitro therapeutic equivalence studies, following the gradual application approach and sanitary risk criteria. Compliance with the new regulation will allow greater access to effective, safe and quality generic drugs. Meanwhile, drugs continue to be marketed in the absence of therapeutic equivalence studies. Findings show that some drugs failed in in vivo and in vitro comparisons with the reference product. This regulation represents a great challenge for manufacturers and holders of sanitary registrations in order to demonstrate the interchangeability of their pharmaceutical products with the reference product.

4.
Arq. gastroenterol ; 57(3): 232-243, July-Sept. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131668

ABSTRACT

ABSTRACT BACKGROUND: Biologics have revolutionized the treatment of inflammatory bowel disease (IBD). However, these drugs had a significant influence on treatment-related costs, which resulted in the development of biosimilars. OBJECTIVE: This systematic review and meta-analysis aimed to evaluate the drug discontinuation rate in the IBD population who switched from originator to biosimilars in real-world switching studies and address potential nocebo effects as reasons for drug discontinuation. METHODS: Medline (via PubMed), EMBASE, Cochrane Library, and abstract databases of selected congresses were screened for reports of monoclonal antibody (mAb) switching with a minimum post-switch follow-up of >6 months or three infusions. All available information on discontinuation rates was assessed. RESULTS: A total of 30 observational studies were included, involving 3,594 patients with IBD. Twenty-six studies reported a switch from infliximab to CT-P13, two studies involved a switch to SB2, and switching information was not available in two studies. The discontinuation rates were 8%, 14%, and 21% at 6, 12, and 24 months, respectively. The main reasons for drug discontinuation and their respective risks were: disease worsening (2%), remission (4%), loss of adherence (4%), adverse events (5%), and loss of response (7%). The quality of the evidence ranged from low to very low depending on the outcome analyzed. Subjective symptoms leading to drug discontinuation were infrequently reported, and the nocebo effect was clearly assessed in just one of the included papers. CONCLUSION: Discontinuation rates following a switch to a biosimilar in patients with IBD increase over time. However, it was not possible to confirm the nocebo effect as a reason for discontinuation. Therefore, long-term studies evaluating the use of biosimilars to monitor adverse events and potential nocebo effects in post-marketing surveillance are still needed.


RESUMO CONTEXTO: Os biológicos revolucionaram o tratamento da doença inflamatória intestinal (DII). Ademais, esses medicamentos influenciaram os custos relacionados ao tratamento. Tal aumento significativo nos gastos com o tratamento motivou desenvolvimento dos biossimilares. OBJETIVO: Esta revisão sistemática e metanálise objetivou avaliar a taxa de descontinuação de medicamentos na população com DII que foi submetida à troca do biológico originador para um biossimilar, em estudos observacionais que abordaram possíveis razões para a descontinuação do tratamento. MÉTODOS: Tendo como base de dados Medline (via PubMed), EMBASE, Cochrane Library e resumos de congressos médicos, foram rastreados artigos com relatos de troca de um biológico originador por um biossimilar, com acompanhamento pós-troca de no mínimo 6 meses ou três infusões. Todas as informações disponíveis sobre as taxas de descontinuação foram avaliadas. RESULTADOS: Foram incluídos no total 30 estudos observacionais, envolvendo 3.594 pacientes com DII. Vinte e seis estudos relataram uma mudança do infliximabe para CT-P13, dois estudos envolveram uma mudança para o SB2, e as informações sobre a troca não estavam disponíveis em dois estudos. As taxas de descontinuação foram de 8%, 14% e 21% aos 6, 12 e 24 meses, respectivamente. Os principais motivos para a descontinuação do medicamento e seus respectivos riscos foram: agravamento da doença (2%), remissão (4%), perda de adesão (4%), eventos adversos (5%) e perda de resposta (7%). A qualidade da evidência variou de baixa a muito baixa, dependendo do resultado analisado. Os sintomas subjetivos que levaram à descontinuação do medicamento foram relatados com pouca frequência, e o efeito nocebo foi claramente avaliado em apenas um dos artigos incluídos. CONCLUSÃO: As taxas de descontinuação após a mudança para um biossimilar em pacientes com DII aumentam com o tempo. No entanto, não foi possível confirmar o efeito nocebo como motivo da descontinuação. Portanto, ainda são necessários estudos em longo prazo avaliando o uso de biossimilares para monitorar eventos adversos e potenciais efeitos nocebo na vigilância pós-comercialização.


Subject(s)
Humans , Inflammatory Bowel Diseases/drug therapy , Biosimilar Pharmaceuticals/therapeutic use , Infliximab/therapeutic use
5.
Rev. méd. Chile ; 148(9)sept. 2020.
Article in Spanish | LILACS | ID: biblio-1389323

ABSTRACT

Background: Vitamin K antagonist medications (VKA) are essential for the prevention of thromboembolic events, but their effectiveness is influenced by multiple factors, such as the type of medication chosen. Aim: To evaluate the efficacy in anticoagulant control of the bioequivalent and non-bioequivalent drugs of acenocoumarol compared to the reference drug. To evaluate the efficacy of warfarin bioequivalents available in Chile. To contrast the overall anticoagulant control efficacy between acenocoumarol and warfarin. Material and Methods: The results of 69333 outpatient oral anticoagulation controls were analyzed. Patient were separated in groups according to the drug that they used. Subsequently, the proportions of controls outside the range for each of acenocoumarol and warfarin bioequivalent drugs were compared. Acenocoumarol non-bioequivalent drugs were also compared with the reference drug. Acenocoumarol was compared with warfarin. Results: Acenocoumarol bioequivalent drugs and the reference drug had a similar proportion of controls outside the range (Odds ratios (OR) 0.812; 0.969; 0.974 and 0.963). Non-bioequivalent drugs had a higher proportion than the reference drug (OR 1.561 and 2.037). Both warfarin brands have a similar proportion of controls outside of the range (OR 1.050). Acenocoumarol compared to warfarin had a significant higher proportion of controls outside the range (OR 1.191). Conclusions: The pharmacological presentation of vitamin K antagonists could influence anticoagulant control. Therefore, it is not prudent to switch these presentations frequently.


Subject(s)
Humans , Thromboembolism , Vitamin K , Anticoagulants , Thromboembolism/prevention & control , Vitamin K/antagonists & inhibitors , Chile , Administration, Oral , Acenocoumarol , Anticoagulants/therapeutic use
6.
CoDAS ; 32(2): e20190121, 2020. tab
Article in Portuguese | LILACS | ID: biblio-1089610

ABSTRACT

RESUMO Objetivo criar uma versão consenso de roteiro de observação fonoaudiológica da expressividade. Método o processo foi dividido em três etapas sendo a primeira levantamento e classificação das variáveis encontradas nos instrumentos apresentados na literatura; e nas etapas 2 e 3, na direção de trabalho coletivo, juízes especialistas (grupo focal I e II) criaram e adequaram, junto com a pesquisadora, a versão consenso do roteiro de avaliação da expressividade. Resultados a lista inicial apresentada aos juízes continha 48 variáveis presentes na literatura, sendo 11 relacionados a aspectos emocionais e de interpretação, 20 à expressividade oral, três a aspectos relacionados à expressividade verbal e, finalmente, 14 à expressividade não verbal. Na etapa 2, a versão inicial do roteiro do grupo focal I resultou num documento com 28 parâmetros distribuídos em três grupos temáticos de avaliação: aspectos gerais de comunicação, com três parâmetros; aspectos relacionados à expressividade oral, com 16; e aspectos relacionados à expressividade corporal, com nove parâmetros. Na etapa 3, a versão consenso, após a adequação do grupo focal II, também foi finalizada com 28 parâmetros, distribuídos em dois eixos temáticos. Conclusão a versão consenso do Roteiro Fonoaudiológico de Observação da Expressividade foi finalizada com 28 parâmetros, distribuídos em dois eixos temáticos sendo: de impacto inicial da comunicação, com seis parâmetros; e expressividade, com 22.


ABSTRACT Purpose To create a consensus version of a speech-language pathology (SLP) script to assess the expressiveness of voice professionals. Methods The process was divided into three stages: stage 1 included a survey of the literature and classification of the variables found in the instruments used; in steps 2 and 3, through teamwork, expert judges (focus groups I and II) created and adapted, along with the researcher, a consensus version of the expressiveness assessment script. Results The initial list presented to the judges contained 48 variables found in the literature: 11 related to emotional and interpretation aspects, 20 associated with oral expressiveness, three related to issues of verbal expressiveness, and 14 related to nonverbal expressiveness. In stage 2, the initial version of the script of the focus group I resulted in a document with 28 parameters, distributed in three thematic assessment groups: general aspects of communication, with three parameters; aspects related to oral expressiveness, with 16 parameters; aspects associated with body expressiveness, with nine parameters. In stage 3, after adequacy by focus group II, the consensus version also resulted in 28 parameters, distributed in two thematic groups. Conclusion The consensus version of the SLP expressiveness assessment script for voice professionals was finalized with 28 parameters, distributed in two thematic axes: initial impact of communication, with six parameters; expressiveness, with 22 parameters.


Subject(s)
Humans , Voice Quality/physiology , Speech-Language Pathology/instrumentation , Voice/physiology , Prospective Studies , Speech-Language Pathology/methods , Consensus
7.
Rev. Soc. Bras. Clín. Méd ; 14(4): 212-216, 2016.
Article in Portuguese | LILACS | ID: biblio-827215

ABSTRACT

OBJETIVO: Avaliar a bioequivalência de duas formulações de cloridrato de propafenona 300mg em comprimido revestido.MÉTODOS: Estudo randomizado, cruzado, aberto, com dois tratamentos, duas sequências e quatro períodos com 60 participantes sadios de ambos os sexos. Os voluntários foram internados em quatro oportunidades durante 24 horas; em cada período, os sujeitos receberam a formulação teste ou a formulação referência, em regime pós-prandial. Foram coletadas 23 amostras de sangue após administração da droga para determinação plasmática da propafenona. Para quantificação da droga, foi utilizada técnica de cromatografia líquida acoplada à espectrometria de massas sequencial. RESULTADOS: As formulações foram consideradas clinicamente bem toleradas. A concentração máxima e a área sob a curva de zero a 36 horas foram comparadas: a média geométrica da razão entre as formulações teste e referência para concentração máxima foi de 110,16%, com intervalo de confiança de 99,44% a 122,04% e coeficiente de variação de 33,95%. A média geométrica da razão entre as formulações teste e referência para a área sob a curva de zero a 36 horas foi de 107,92%, com intervalo de confiança de 99,58% a 116,96% e coeficiente de variação de 26,39%. A média geométrica da razão entre o medicamento teste e referência para área sob a curva de zero ao infinito foi de 107,12%, com intervalo de confiança de de 99,11% a 115,78% e coeficiente de variação de 25,48%. CONCLUSÃO: As formulações teste e referência foram estatisticamente bioequivalentes, de acordo com sua taxa e extensão de absorção.


OBJECTIVE: To evaluate the bioequivalence of two 300mg profanone hydrochloride coated tablets. METHODS: Randomized, cross-over, openstudy, with two treatments, two sequences, and four periods with 60 healthy participants of both genders. The volunteers were admitted in four opportunities over 24 hours; on each period, the subjects received a test formulation, or a reference formulation, in a postprandial administration. Twenty-three samples of blood were collected after oral administration of the drug for determining plasma level of propafenone. Liquid chromatography-mass spectrometry was used for quantifying propafenone. RESULTS: The formulations were considered clinically well tolerated. The maximum concentration and the area under the curve from zero to 36 hours were compared: the geometric mean of the ratio between the test and reference formulations for maximum concentration was 110.16%, with confidence interval of 99.44% - 122.04%), coefficient of variation of 33.95%. The geometric mean of the ratio between the test and reference formulations for the area under the curve of zero to 36 hours was 107.92%, with confidence interval of 99.58% - 116.96%, and coefficient of variation of 26.39%. The geometric mean of the ratio between the formulations for area under the curve of zero to infinitum as 107.12% with confidence interval of 99.11% - 115.78%),and coefficient of variation of 25.48%. CONCLUSION: According to the rate and extension of absorption, the test and reference formulations are statistically bioequivalent.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Anti-Arrhythmia Agents , Postprandial Period/drug effects , Propafenone/administration & dosage , Propafenone/pharmacokinetics , Blood
8.
Cancer Research and Treatment ; : 1120-1129, 2016.
Article in English | WPRIM | ID: wpr-68882

ABSTRACT

PURPOSE: This study was designed to characterize the pharmacokinetic profile and to assess bioequivalence of the sponsor's test formulation (imatinib mesylate 400 mg tablets) with an innovator product (Gleevec 400 mg tablets, Novartis Pharmaceuticals) under fed conditions, in adult patients of Philadelphia chromosome positive chronic myeloid leukemia (Ph+ CML) stabilized on imatinib mesylate 400 mg. In addition, the aim of this study was to monitor the safety profile of investigational medicinal products (IMPs). MATERIALS AND METHODS: A multicenter, randomized, open label, two-period, crossover, single dose bioequivalence study was designed for conduct under fed conditions in 42 adult Ph+ CML patients already stabilized on imatinib 400 mg tablets. Pharmacokinetic parameters Tmax, Cmax, and AUC0-24 were calculated using a non-compartmental model on validated WinNonlin software. Validated SAS software was used for statistical evaluation of data. The safety profile of investigational products was monitored during the course of study by applying a clinical process for recording observed untoward effects postadministration of investigational products. RESULTS: The 90% confidence intervals for the test/reference mean ratios of the ln-transformed PK variables Cmax (99.0%) and AUC0-24 (99.2%) were within an acceptable range of 80%-125%, as per bioequivalence assumptions. Both formulations were well tolerated after oral administration of IMPs. CONCLUSION: The test product was found to be bioequivalent and safe, and thus can be used interchangeably in clinical practice.


Subject(s)
Adult , Humans , Administration, Oral , Imatinib Mesylate , Leukemia , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Mesylates , Pharmacokinetics , Philadelphia Chromosome , Tablets , Therapeutic Equivalency
9.
RBM rev. bras. med ; 72(4)abr. 2015.
Article in Portuguese | LILACS | ID: lil-749251

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade da associação em dose fixa de memantina 20 mg e donepezila 10 mg comprimido revestido (Aché Laboratórios Farmacêuticos S.A., formulação teste) e Ebix® 10 mg comprimido revestido (Lundbeck Brasil Ltda., formulação referência) e Eranz® 10 mg comprimido revestido (Wyeth Indústria Farmacêutica Ltda, formulação referência) em 36 voluntários de ambos os sexos. O estudo foi aberto, aleatorizado, 2-tratamentos, 2-sequências, 2-períodos, cruzado, dose única, nos quais um grupo de voluntários recebeu a formulação teste e outro as formulações de referências administradas concomitantemente. As amostras de sangue foram obtidas ao longo de um intervalo de 96 horas. As concentrações de memantina e donepezila foram determinadas através de espectrometria de massa (UPLC-MS-MS), utilizando amantadina e loratadina como padrão interno. A média geométrica de memantina associada a donepezila/Ebix® 10 mg foi de 98,75% para ASC0-t e 96,95% para "Cmáx". Os intervalos de confiança de 90% foram de 96,01%-101,58% e 93,50%-100,54%, respectivamente. A média geométrica de memantina associada a donepezila/Eranz® 10 mg foi de 92,03% para ASC0-t e 94,77% para "Cmáx". Os intervalos de confiança de 90% foram de 89,47%-94,67% e 88,22%-101,80%, respectivamente. Uma vez que os intervalos de confiança de 90% para "Cmáx" e ASC0-t estiveram dentro da faixa de 80%-125% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que o comprimido de memantina 20 mg associado a donepezila 10 mg foi bioequivalente à administração concomitante de dois comprimidos de Ebix® 10 mg e 1 comprimido de Eranz® 10 mg e, desta forma, o produto teste pode ser considerado intercambiável na prática médica.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Biological Availability , Therapeutic Equivalency , Chromatography , Pharmacokinetics , Memantine
10.
Article in Portuguese | LILACS-Express | LILACS | ID: lil-750862

ABSTRACT

Este estudo teve por objetivo avaliar a bioequivalência entre dois produtos contendo Clozapina 100 mg (produto teste: LifalClozapina® da Lifal ? Laboratório Industrial Farmacêutico de Alagoas S/A. O produto referência: Leponex® do Laboratório Novartis Biociências S/A.) em 40 voluntários. O estudo foi aberto, randomizado, do tipo cross-over, em estado de equilíbrio, com dois períodos (duas sequências), nos quais os voluntários receberam, em cada período, a formulação teste ou a formulação referência. A biodisponibilidade relativa das formulações seguidas à administração oral foi avaliada com base em comparações estatísticas de parâmetros farmacocinéticos relevantes obtidos de dados de amostra sanguínea dos voluntários, sendo as amostras coletadas em período de 24h. A concentração de Clozapina foi medida a partir de método analítico apropriado e válido. As medidas farmacocinéticas utilizadas foram: Cmin, Cmax e ASCt. As diferenças médias (± DP) entre referência e teste foram: 0,1615 ± 0,3404 (ng/mL); -0,0969 ± 0,4131 (ng/mL) e 0,9143 ± 3,9941 (ng*h/mL). Os intervalos de confiança para biequivalência média atenderam aos limites determinados pela Agência Nacional de Vigilância Sanitária (ANVISA) de 80 a 125%, sendo os dois medicamentos considerados bioequivalentes. Assim, produtos teste e referência são considerados intercambiáveis.


This study aimed to evaluate the bioequivalence between two products containing Clozapine 100 mg (testing product: LifalClozapina® from Lifal ? Industrial Pharmaceutical Laboratory of Alagoas S/A and the reference product: Leponex® from the Novartis Biociências S/A. Laboratories) in 40 volunteers. The study was open, randomized, crossover type, in a state of equilibrium, with two periods (two sequences) in which volunteers were given, in each period, the testing formulation or the reference formulation. The relative bioavailability of the formulations following oral administration was evaluated based on statistical comparisons of relevant pharmacokinetic parameters obtained from blood samples in a 24 hours period. The concentration of Clozapine was measured using an appropriate and valid analytical method. The pharmacokinetic measures used were: Cmin and Cmax, and ASCt. The mean differences (± SD) between reference and testing were: 0.1615 ± 0.3404 (ng/mL); -0.0969 ± 0.4131 (ng/mL); and 0.9143 ± 3.9941 (ng*h/ mL). The confidence intervals for medium bioequivalence met the limits determined by the National Agency of Sanitary Surveillance (ANVISA) of 80 to 125%, and both medications were considered bioequivalent. Thus, the testing and reference products are considered interchangeable

11.
São Paulo; s.n; 2015. [85] p. ilus, tab, graf.
Thesis in Portuguese | LILACS | ID: biblio-870755

ABSTRACT

A aplicação de toxina botulínica A no lado não paralisado (LNP) é feita para tratar a assimetria resultante da paralisia facial (PF). As unidades de toxina onabotulinica A (Ona) e toxina abobotulinica A (Abo) não são equivalentes. Comparou-se a taxa de conversão de 1:3 em pacientes com PF. Cinquenta e cinco pacientes (idade entre 16 e 67 anos, 43 mulheres), com PF de longa duração foram tratados de forma aleatória com a aplicação de Ona (n = 25) ou Abo (n = 30) no LNP. Efeitos adversos, simetria facial, satisfação subjetiva e Índice de Incapacidade Facial (IIF) foram avaliados após 1 e 6 meses. Os resultados mostraram que a incidência de efeitos adversos foi maior com Abo (93,3% vs. 64,0%, p = 0,007). Avaliação Clínica do LNP diminuiu após 1 mês e aumentou novamente aos 6 meses, sem diferenças entre os grupos. A nota do lado paralisado (LP) foi menor no grupo Ona antes do tratamento, mas semelhante em ambos os grupos depois do tratamento. A nota do LP aumentou depois de 1 mês, e aos 6 meses foi ainda maior que a nota de prétratamento em ambos os grupos. A avaliação subjetiva melhorou em todos os momentos em comparação com a nota do pré-tratamento e diferiu entre os dois grupos apenas em 1 mês, quando o grupo Abo ficou um pouco mais paralisado. Índice de Função Física (IFF) e Índice de Bem-Estar Social (IBES), subescalas do Índice de Incapacidade Facial (IFF), entre os dois grupos não foram diferentes. Concluímos que ambas as toxinas reduziram a assimetria de forma eficiente em pacientes com FP. Os efeitos adversos foram maiores com Abo na equivalência de 1:3.


Botulinum toxin A injection into the nonparalyzed side (NPS) is used to treat asymmetry resulting from facial palsy (FP). OnabotulinumtoxinA (ONA) and abobotulinumtoxinA (ABO) units are not equivalent. We compared the conversion ratio of 1:3 in patients with FP. Fifty-five patients (aged 16-67 years, 43 women) with long-standing FP were randomly treated with either ONA (n = 25) or ABO (n = 30) injections into the NPS. Adverse effects, facial symmetry, subjective satisfaction, and Facial Disability Index (FDI) were assessed after 1 and 6 months. The results showed that the incidence of adverse effects was higher with ABO (93.3% vs. 64.0%, p = 0.007). Clinical scores of the NPS decreased after 1 month and increased again at 6 months, with no betweengroup differences. Scores of the paralyzed side were lower in the ONA group before treatment, but similar in both groups thereafter. The paralyzed side scores increased after 1 month, and at 6 months were still higher than the pretreatment scores in both groups. Subjective assessment improved at all time points compared to pretreatment score and differed between the two groups only at 1 month, when the ABO group was a bit too paralyzed. The Physical Function and Social/Well-Being Function subscales of the FDI did not differ between the two groups. We conclude that both toxins efficiently reduced asymmetry in patients with FP. Adverse effects were higher with ABO at an equivalence ratio of 1:3.


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Adult , Middle Aged , Aged , Facial Asymmetry , Facial Paralysis/therapy , Quality of Life , Therapeutic Equivalency , Botulinum Toxins, Type A/antagonists & inhibitors , Botulinum Toxins, Type A/adverse effects
12.
RBM rev. bras. med ; 71(11)nov. 2014.
Article in Portuguese | LILACS | ID: lil-737087

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade de duas formulações de levofloxacino 500 mg comprimido revestido (levofloxacino da Biosintética Farmacêutica Ltda.) formulação teste e Tavanic® da Sanofi-Aventis Farmacêutica Ltda. formulação referência, Brasil) em 28 voluntários de ambos os sexos. O estudo foi aberto, aleatorizado, 2-sequências, 2-períodos, cruzado, dose única com 2 tratamentos, nos quais um grupo de voluntários recebeu a formulação teste e outro a formulação referência. As amostras de sangue foram obtidas ao longo de um intervalo de 48 horas. As concentrações de levofloxacino foram determinadas através de Espectrometria de Massa (HPLC-MS-MS), utilizando ciprofloxacino como padrão interno. A partir dos dados obtidos calcularam-se os seguintes parâmetros farmacocinéticos: ASC0-t, ASC0-¥ e "Cmax". A média geométrica de Levofloxacino/Tavanic® 500 mg foi de 107,00% para ASC0-t, 107,07% para ASC0-¥ e 106,70% para "Cmax". Os intervalos de confiança de 90% foram de 103,06%-111,09%, 103,16%-111,13% e 96,27%-118,27% , respectivamente. Uma vez que os intervalos de confiança de 90% para "Cmax" e ASC0-t estiveram dentro da faixa de 80 - 125% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que o comprimido de levofloxacino de 500 mg foi bioequivalente ao comprimido de Tavanic® de 500 mg e, desta forma, o produto teste pode ser considerado intercambiável na prática médica.

13.
RBM rev. bras. med ; 71(8)ago. 2014.
Article in Portuguese | LILACS | ID: lil-725913

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade/bioequivalência de duas formulações de topiramato 100 mg comprimidos revestidos (Aché Laboratórios Farmacêuticos S/A - formulação teste e Topamax® por Janssen Cilag Farmacêutica Ltda.) em 28 voluntários de ambos os sexos. O estudo foi realizado através de um desenho aberto, randomizado, cruzado em dois períodos com tempo de washout de 14 dias. As amostras de plasma de 23 dos 28 voluntários inicialmente incluídos foram obtidas ao longo de um intervalo de 120 horas. As concentrações de topiramato foram determinadas através de um equipamento LC-MS-MS, utilizando prednisona como padrão interno. A partir dos dados obtidos se calcularam os seguintes parâmetros farmacocinéticos: ASC0-t, ASC0-¥ e Cmax. A razão das médias geométricas de Topiramato/Topamax® 100 mg foi de 100,97% para ASC0-t, 101,38% para ASC0-¥ e 96,94% para Cmax; os intervalos de confiança de 90% foram de 107,02% - 107,40%, 104,45% - 110,42% e 90,98% - 103,29%, respectivamente. Uma vez que os intervalos de confiança de 90% para Cmax e ASC0-t estiveram dentro da faixa de 80% a 125% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que comprimido revestido de topiramato 100 mg foi bioequivalente ao comprimido de Topamax® de 100 mg e, desta forma, o produto teste pode ser considerado intercambiável na prática médica...


Subject(s)
Adolescent , Young Adult , Middle Aged , Chromatography , Biological Availability , Therapeutic Equivalency , Pharmacokinetics
14.
RBM rev. bras. med ; 71(6/7)jun.-jul. 2014.
Article in Portuguese | LILACS | ID: lil-724177

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade de duas formulações de desloratadina, sendo a formulação teste desloratadina solução oral (Esalerg Gotas) de 1,25 mg/mL (Aché Laboratórios Farmacêuticos S.A.) e a formulação referência Desalex® xarope de 0,5 mg/mL (Mantecorp Indústria Química e Farmacêutica) em 48 voluntários de ambos os sexos. O estudo foi aberto, aleatorizado, 2-sequências, 2-períodos, cruzado, dose única com dois tratamentos, nos quais um grupo de voluntários recebeu a formulação teste e outro a formulação referência. As amostras de sangue foram obtidas ao longo de um intervalo de 72 horas. As concentrações de desloratadina foram determinadas através de Espectrometria de Massa (UPLC-MS-MS), utilizando donepezil como padrão interno. A partir dos dados obtidos calcularam-se os seguintes parâmetros farmacocinéticos: ASC0-t, ASC0-¥ e Cmax. A média geométrica de desloratadina/Desalex® foi de 95,42% para ASC0-t, 95,30% para ASC0-¥ e 90,61% para Cmax. Os intervalos de confiança de 90% foram 91,48% - 99,53% para ASC0-t, 91,18% - 99,61% para ASC0-¥ e 85,32% - 96,22% para Cmax. Uma vez que os intervalos de confiança de 90% para Cmax e ASC0-t estiveram dentro da faixa de 80%-25% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que a solução oral de desloratadina 1,25 mg/mL (Esalerg Gotas) foi bioequivalente ao xarope 0,5 mg/mL (Desalex®) e desta forma o produto teste pode ser considerado intercambiável na prática médica...


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Middle Aged , Chromatography , Biological Availability , Therapeutic Equivalency , Pharmacokinetics
15.
RBM rev. bras. med ; 71(4)abr. 2014.
Article in Portuguese | LILACS | ID: lil-721596

ABSTRACT

O estudo foi realizado para comparar a bioequivalência de duas formulações de pregabalina, Dorene cápsula gelatinosa dura de 150 mg (pregabalina do Aché Laboratórios Farmacêuticos S/A, formulação teste) e Lyrica® (pregabalina da Pfizer Manufacturing Deutschland Gmbh, Brasil, formulação referência), em 32 voluntários sadios do sexo masculino. O estudo foi realizado através de um desenho aberto, randomizado, dois tratamentos (referência e teste), duas sequências (RT e TR), cruzado em dois períodos com tempo de washout de dez dias. As amostras de plasma foram obtidas ao longo de um intervalo de 48 horas. As concentrações de pregabalina foram determinadas através de um equipamento UPLC/MS/MS, utilizando gabapentina como padrão interno. A partir dos dados de concentração plasmática obtidos individualmente, calcularam-se os seguintes parâmetros farmacocinéticos: ASC0-t, Cmax e Tmax. As médias para ASC0-48 para as formulações teste e referência foram 26127,511 ng.h/mL e 26174,410 ng.h/mL, para Cmax foram 4367,727 ng/mL e 4238,842 ng/mL e para Tmax foram 0,903 h e 1,016 h, respectivamente. As razões das médias geométricas foram de 100,04 % para ASC0-48, e 104,42 % para Cmax. Os intervalos com 90% de confiança foram 97,79 - 102,33% para ASC0-48, e 97,39 - 111,95% para Cmax. Uma vez que os intervalos de confiança de 90% para Cmax e ASC0-48 estiveram dentro da faixa de 80% a 125% proposta pelo Food and Drug Administration (FDA) e pela ANVISA (Agência Nacional de Vigilância Sanitária) conclui-se que cápsula gelatinosa dura de pregabalina de 150 mg (Dorene) é bioequivalente à cápsula gelatinosa dura de Lyrica® de 150 mg e, desta forma, o produto teste pode ser considerado intercambiável na prática médica...


Subject(s)
Humans , Biological Availability , Chromatography , Pharmacokinetics
16.
RBM rev. bras. med ; 71(3)mar. 2014.
Article in Portuguese | LILACS | ID: lil-718711

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade de duas formulações de desloratadina xarope de 0,5 mg/mL, sendo estas, Esalerg® xarope de 0,5 mg/mL (Aché Laboratórios Farmacêuticos S.A. formulação teste) e Desalex® xarope de 0,5 mg/mL (Mantecorp Indústria Química e Farmacêutica, formulação referência) em 36 voluntários de ambos os sexos. O estudo foi aberto, aleatorizado, 2-sequências, 2-períodos, cruzado, dose única com dois tratamentos, nos quais um grupo de voluntários recebeu a formulação teste e outro a formulação referência. As amostras de sangue foram obtidas ao longo de um intervalo de 72 horas. As concentrações de desloratadina foram determinadas através de Espectrometria de Massa (UPLC-MS-MS), utilizando donepezil como padrão interno. A partir dos dados obtidos calcularam-se os seguintes parâmetros farmacocinéticos: ASC0-t e Cmax. A média geométrica de desloratadina/Desalex® foi de 112,88% para ASC0-t e 110,04% para Cmax. Os intervalos de confiança de 90% foram 106,79 - 119,32% para ASC0-t e 102,83 - 117,76% para Cmax. Uma vez que os intervalos de confiança de 90% para Cmax e ASC0-t estiveram dentro da faixa de 80% a 125% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que o xarope de desloratadina 0,5 mg/mL (Esalerg®) foi bioequivalente ao xarope 0,5 mg/mL (Desalex®) e desta forma o produto teste pode ser considerado intercambiável na prática médica.

17.
RBM rev. bras. med ; 70(7)jun. 2013.
Article in Portuguese | LILACS | ID: lil-683422

ABSTRACT

O estudo foi realizado para comparar a bioequivalência de duas formulações de levodopa 200 mg + benserazida 50 mg (equivalente a 57 mg de cloridrato de benserazida) sob a forma de comprimidos (levodopa + cloridrato de benserazida do Aché Laboratórios Farmacêuticos S/A, formulação teste e Prolopa® de Produtos Roche Químicos e Farmacêuticos S/A, formulação referência) em 36 voluntários sadios. O estudo foi realizado através de um desenho aberto, randomizado, cruzado em dois períodos com tempo de washout de quatro semanas. As amostras de plasma foram obtidas ao longo de um intervalo de 96 horas. As concentrações de levodopa e do metabólito 3-O-metildopa foram determinadas através de um equipamento HPLC/MS/MS, utilizando carbidopa como padrão interno. A partir dos dados de concentração plasmática obtidos individualmente se calcularam os seguintes parâmetros farmacocinéticos: ASC0-t, Cmáx e Tmáx...


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Benserazide , Chromatography , Biological Availability , Therapeutic Equivalency , Pharmacokinetics , Levodopa
18.
RBM rev. bras. med ; 70(3)mar. 2013.
Article in Portuguese | LILACS | ID: lil-683410

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade relativa de duas formulações orais de cloridrato de ranitidina, sendo a formulação teste cloridrato de ranitidina suspensão oral de 40 mg/ml (Aché Laboratórios Farmacêuticos S/A) e a formulação referência Antak® xarope de 150 mg/10 ml produzida por Glaxo Smith Kline Brasil Ltda. em 36 voluntários de ambos os sexos. O estudo foi realizado através de um desenho aberto, randomizado, cruzado em dois períodos com tempo de washout de quatro dias. As amostras de plasma de 34 dos 36 voluntários inicialmente incluídos foram obtidas ao longo de um intervalo de 12 horas. As concentrações de ranitidina foram determinadas através de um equipamento LC-MS-MS, utilizando cimetidina como padrão interno. A partir dos dados obtidos, calcularam-se os seguintes parâmetros farmacocinéticos: ASC0-t , ASC0-¥ e Cmax. A razão das médias geométricas de Ranitidina/Antak® foi de 99,75% para ASC0-t, 100,24% para ASC0-¥ e 98,87% para Cmax; os intervalos de confiança de 90% foram de 93,91%-105,95%, 94,47%-106,37% e 88,79%-110,09%, respectivamente. Uma vez que os intervalos de confiança de 90% para Cmax, e ASC0-t estiveram dentro da faixa de 80% a 125% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que a solução oral de cloridrato de ranitidina 40 mg/ml foi bioequivalente a de Antak® 150 mg/10 ml e, dessa forma, o produto teste pode ser considerado intercambiável na prática médica...


Subject(s)
Humans , Male , Female , Young Adult , Middle Aged , Chromatography , Biological Availability , Therapeutic Equivalency , Pharmacokinetics , Ranitidine
19.
Journal of Korean Society for Clinical Pharmacology and Therapeutics ; : 34-40, 2013.
Article in Korean | WPRIM | ID: wpr-194551

ABSTRACT

BACKGROUND: Voglibose, an inhibitor of alpha-glucosidase of the small intestine brush border, is used to treat type 2 diabetic patients. Bioequivalence test based on pharmacokinetic parameters is difficult because voglibose does not cross the enterocytes after ingestion. This study was conducted to establish bioequivalence of two formulations of 0.3-mg voglibose with pharmacodynamic endpoints. METHODS: This study was an open, single-dose, randomized, 6-sequence, 3-period crossover design in healthy volunteers. In each period, subjects received placebo or three tablets of either test formulation or reference formulation with sucrose, with a 7-day washout period each dosing period. Serial blood samples were collected after each administration. The maximum concentrations of serum glucose and serum insulin (C(max)(G) and C(max)(I)) and the area under the serum concentration - time curve from dosing to 2 or 4 hours after dosing for serum glucose and insulin (AUC(0-2h)(G), AUC(0-4h)(G), AUC(0-2h)(I) and AUC(0-4h)(I), respectively) were determined by noncompartmental analysis. Formulation-related differences were tested in accordance with the Korean regulatory bioequivalence criteria. RESULTS: A total of 54 subjects completed study in accordance with protocol. The geometric mean ratios (GMRs) of the test formulation to the reference formulation for Cmax(G), AUC(0-2h)(G), AUC(0-4h)(G), C(max)(I), AUC(0-2h)(I) and AUC(0-4h)(I) were 0.945, 1.014, 0.995, 0.937, 0.985 and 0.983, respectively and the 90% confidence intervals (CIs) of corresponding values were 0.985-1.026, 0.991-1.038, 0.977-1.014, 0.830-1.057, 0.901-1.078 and 0.911-1.014, respectively. CONCLUSION: This single-dose study found that two formulations of 0.3-mg voglibose did not meet the regulatory criteria for bioequivalence in these healthy volunteers.


Subject(s)
Humans , alpha-Glucosidases , Cross-Over Studies , Eating , Enterocytes , Glucose , Inositol , Insulin , Intestine, Small , Microvilli , Sucrose , Tablets , Therapeutic Equivalency
20.
RBM rev. bras. med ; 69(11)nov. 2012.
Article in Portuguese | LILACS | ID: lil-663157

ABSTRACT

O estudo foi realizado para comparar a biodisponibilidade de duas formulações de Valsartana 320 mg comprimido revestido (Valsartana do Aché Laboratórios Farmacêuticos S/A formulação teste e Diovan® da Novartis Biociências S.A. formulação referência, Brasil) em 108 voluntários de ambos os sexos. O estudo foi aberto, aleatorizado, 2-sequências, 2-períodos, cruzado, dose única com dois tratamentos, nos quais um grupo de voluntários receberam a formulação teste e outro a formulação referência. As amostras de sangue foram obtidas ao longo de um intervalo de 48 horas. As concentrações de valsartana foram determinadas através de espectrometria de massa (HPLC-MS-MS), utilizando losartana como padrão interno. A partir dos dados obtidos, calcularam-se os seguintes parâmetros farmacocinéticos: ASC0-t, ASC0-¥ e Cmax. A média geométrica de Valsartana/Diovan® 320 mg foi de 103,63% para ASC0-t, 102,72% para ASC0-¥ e 102,96% para Cmax. Os intervalos de confiança de 90% foram de 96,24%-111,59%, 95,64%-110,34% e 95,51%-110,98%, respectivamente. Uma vez que os intervalos de confiança de 90% para Cmax e ASC0-t estiveram dentro da faixa de 80%-125% proposta pelo FDA e pela ANVISA (Agência Nacional de Vigilância Sanitária do Brasil), conclui-se que o comprimido revestido de valsartana de 320 mg foi bioequivalente ao comprimido revestido de Diovan® de 320 mg e, dessa forma, o produto teste pode ser considerado intercambiável na prática médica.

SELECTION OF CITATIONS
SEARCH DETAIL